Publikationen zum Thema Spiroergometrie


In der Tabelle finden Sie eine umfangreiche Übersicht über nationale und internationale Publikationen/Artikel, in denen CORTEX-Systeme vorgestellt und verwendet werden. 
Einige Artikel stehen als PDF zum Download zur Verfügung. Andere Beiträge werden mit einem Abstrakt vorgestellt. Hierbei wird auf den Herausgeber und die Autoren verwiesen.

 

  • Nr Titel Autoren/Institut Segement Produkt
  • 2017-056 Exercise Intolerance in HFpEF: Diagnosing and Ranking its Causes Using Personalized O2 Pathway Analysis Houstis NE, Eisman AS, Pappagianopoulos PP, Wooster L, Bailey CS, Wagner PD, Lewis GD Mass. General, Boston
Produktbereich:
Veröffentlichung:
Sprache:
Verlag/Herausgeber: Circulation. 2017 Oct 9. pii

Background -Heart failure with preserved ejection fraction (HFpEF) is a common syndrome with a pressing shortage of therapies. Exercise intolerance is a cardinal symptom of HFpEF, yet its pathophysiology remains uncertain. Methods -We investigated the mechanism of exercise intolerance in each of 134 patients referred for cardiopulmonary exercise testing (CPET): 79 with HFpEF and 55 controls. We performed CPET with invasive monitoring to measure hemodynamics, blood gases, and gas exchange during exercise. We used these measurements to quantify 6 steps of oxygen transport and utilization (the “O2 pathway”) in each HFpEF patient, identifying the defective steps that impair each one’s exercise capacity (peak VO2). We then quantified the functional significance of each O2 pathway defect by calculating the improvement in exercise capacity a patient could expect from correcting the defect. Results -Peak VO2 was reduced by 34%±2% (mean±SEM, P<0.001) in HFpEF compared with controls of comparable age, gender, and body mass index. The vast majority (97%) of HFpEF patients harbored defects at multiple steps of the O2 pathway, the identity and magnitude of which varied widely. Two of these steps, cardiac output and skeletal muscle O2 diffusion, were impaired relative to controls by an average of 27±3% and 36±2%, respectively (P<0.001 for both). Due to interactions between a given patient’s defects, the predicted benefit of correcting any single one was often minor; on average, correcting a patient’s cardiac output led to a 7±0.5% predicted improvement in exercise intolerance, while correcting a patient’s muscle diffusion capacity led to a 27±1% improvement. At the individual level, the impact of any given O2 pathway defect on a patient’s exercise capacity was strongly influenced by comorbid defects. Conclusions -Systematic analysis of the O2 pathway in HFpEF showed that exercise capacity was undermined by multiple defects, including reductions in cardiac output and skeletal muscle diffusion capacity. An important source of disease heterogeneity stemmed from variation in each patient’s personal profile of defects. Personalized O2 pathway analysis could identify patients most likely to benefit from treating a specific defect; however, the system properties of O2 transport favor treating multiple defects at once, as with exercise training.


zurück zur Übersicht
© CORTEX Biophysik GmbH • Walter-Köhn-Str. 2d • 04356 Leipzig/Germany • Tel: +49 341 - 487 49-0 • info@cortex-medical.de

Wir respektieren Ihre Privatsphäre.

Um unsere Webseite für Sie optimal zu gestalten und fortlaufend verbessern zu können, verwenden wir Cookies. Durch die weitere Nutzung der Webseite stimmen Sie der Verwendung von Cookies zu. Weitere Informationen zu Cookies erhalten Sie in unserer Datenschutzerklärung.